ResilientX

NIS2 compliance your board can approve and your authority can verify

20 controls pre-loaded in ResilientX Security GRC

Directive (EU) 2022/2555 (NIS2 Directive)

Adopted
14 December 2022, by the European Parliament and the Council of the EU
Application
In force since 16 January 2023; national transposition due by 17 October 2024
Who must comply
Essential and important entities in the 18 sectors of Annexes I and II, generally medium-sized and larger
Maximum fines
At least €10 million or 2% of worldwide annual turnover (essential entities); €7 million or 1.4% (important entities)

At a glance · Directive (EU) 2022/2555 (NIS2 Directive)

What is NIS2?

NIS2 is the EU directive on measures for a high common level of cybersecurity across the Union. Adopted on 14 December 2022 and in force since 16 January 2023, it replaced the first NIS Directive (Directive (EU) 2016/1148), which was repealed from 18 October 2024. It extends the scope to 18 sectors, split between sectors of high criticality (Annex I) and other critical sectors (Annex II), and sorts the organisations in scope into essential and important entities.

Because it is a directive, its obligations reach you through national law: Member States had to transpose it by 17 October 2024. In Italy that law is Legislative Decree 138/2024, with the National Cybersecurity Agency (ACN) as the competent authority; the basic security measures ACN requires of NIS entities are built on the 2025 edition of the national framework (FNCDP).

Three articles carry the duties for entities. Article 20 has the management body approve the cybersecurity risk-management measures, oversee their implementation and follow training, and it can be held liable for infringements. Article 21 requires appropriate and proportionate technical, operational and organisational measures, with ten minimum measures that run from risk analysis to multi-factor authentication. Article 23 sets the reporting of significant incidents: an early warning within 24 hours of becoming aware, an incident notification within 72 hours and a final report within one month of the notification. Member States must provide for maximum fines of at least €10 million or 2% of worldwide annual turnover, whichever is higher, for essential entities, and of at least €7 million or 1.4% for important entities.

Who it applies to

  • Medium-sized and larger organisations in the Annex I sectors of high criticality, such as energy, transport, health, water and digital infrastructure
  • Medium-sized and larger organisations in the Annex II sectors, such as postal and courier services, waste management, food, chemicals, manufacturing and digital providers
  • Some entities whatever their size: providers of public electronic communications networks or services, trust service providers, TLD name registries and DNS service providers
  • Public administration entities of central government and, following a risk-based assessment, of regional government
  • Suppliers to these entities: not always in scope themselves, but asked for security guarantees under Article 21(2)(d)

Key dates

  1. 2022

    Adopted

    14 December 2022, by the European Parliament and the Council of the EU

  2. 2023

    Application

    In force since 16 January 2023

  3. 2024

    Application

    National transposition due by 17 October 2024

What NIS2 requires

The ResilientX Security NIS2 library covers the articles that place duties on essential and important entities: 20 controls across Articles 20, 21 and 23 of the Directive, each with guidance on what it requires, how to implement it, what good looks like and the evidence auditors accept. The controls follow the Directive’s own article numbering; your national transposition law sets the binding detail. Below they are grouped by article.

Where the requirements sit

  1. Art. 202 controls

    Governance

    The management body approves the cybersecurity risk-management measures, oversees their implementation and can be held liable for infringements. Its members must follow cybersecurity training, and entities are encouraged to offer similar training to their staff regularly.

    10% of the controls

  2. Art. 21(1)1 control

    Appropriate and proportionate measures

    Technical, operational and organisational measures matched to your risks, taking into account the state of the art, relevant standards and the cost of implementation, and proportionate to your exposure, your size and the likelihood and severity of incidents.

    5% of the controls

  3. Art. 21(2)10 controls

    The ten risk-management measures

    Points (a) to (j): risk analysis and security policies; incident handling; business continuity, backups and crisis management; supply chain security; security in acquisition, development and maintenance, with vulnerability handling and disclosure; assessing the effectiveness of measures; basic cyber hygiene and training; cryptography and encryption; HR security, access control and asset management; multi-factor authentication and secured communications.

    50% of the controls

  4. Art. 21(3)–(5)3 controls

    Supply-chain assessments, corrective measures and technical requirements

    What to weigh when choosing supply chain measures (the vulnerabilities specific to each direct supplier, the overall quality of its products and cybersecurity practices, the EU coordinated risk assessments of critical supply chains); corrective measures without undue delay when you find a gap; and the technical and methodological requirements of Implementing Regulation (EU) 2024/2690 for certain digital infrastructure and digital providers.

    15% of the controls

  5. Art. 234 controls

    Incident reporting

    Notification of significant incidents to your CSIRT or competent authority in stages: early warning within 24 hours of becoming aware, incident notification within 72 hours, final report within one month. Includes the test for when an incident is significant and, where appropriate, informing the recipients of your services about incidents and significant cyber threats.

    20% of the controls

Ready-made control library

20 controls pre-loaded in ResilientX Security GRC

Book a demo

How the ResilientX Security platform covers NIS2

ResilientX Security GRC holds the 20 controls, their owners and the evidence; the other ResilientX Security products supply the data that the supply chain, vulnerability and testing measures need. Whether you are in scope, and as an essential or an important entity, is a legal assessment that stays with your counsel and your national authority; the platform keeps the record that shows the work.

Compliance

Compliance & Risk Management

  • Articles 20, 21 and 23, pre-loaded

    Start from the 20-control NIS2 library. Mark each control for applicability and implementation status, assign an owner and link policies and evidence. NIS2, ISO 27001, DORA and GDPR are cross-mapped, so a control assessed once carries its status to every framework that shares it.

  • Approval and oversight on the record (Art. 20)

    Route security policies through a versioned approval workflow, collect acknowledgements by role or department, and give the management body dashboards of open risks and overdue work. Keep training attendance as evidence with an expiry date, so the next refresher is not missed.

  • Risk analysis, assets and corrective actions

    Score risks on the matrix your methodology uses (5x5, 4x4 or 3x3) and link them to the controls, assets and suppliers involved. Keep systems, processes and business functions in one inventory, and track every gap as a remediation task with an owner, a due date and a full history, so the corrective measures of Article 21(4) are documented.

Learn more — Compliance & Risk Management

Third-Party Risk Management

  • Supply chain security (Art. 21(2)(d))

    Keep the supplier register with criticality tiers and NIS2-related fields, send security questionnaires with automated reminders, and monitor each supplier’s external cyber posture continuously with ResilientX Security TPRM. Suppliers answer from the free Trust Center, where they can also report incidents to the customers affected.

Learn more — Third-Party Risk Management

NIS2 on one platform

  • Controls
  • Evidence
  • Risks
  • Suppliers
  • Findings

Resilience

Unified Exposure Management

  • Vulnerabilities and exposure (Art. 21(2)(e))

    ResilientX Security Unified Exposure Management continuously discovers your internet-facing assets, shadow IT included, and raises real-time alerts on vulnerabilities, cloud misconfigurations, code issues and leaked credentials. Vulnerability handling and the asset inventory start from current data.

Learn more — Unified Exposure Management

Service · Advanced Penetration Testing

Testing that the measures work (Art. 21(2)(f))

Article 21(2)(f) asks for policies and procedures to assess whether your measures are effective. Our penetration tests cover networks, web applications and APIs, legacy and OT systems, using OWASP and OSSTMM methods, with red teaming where you need it. The report documents what held and what to fix.

See the service

Requirement by requirement

Where each application feeds a requirement area with evidence or day-to-day operations. Compliance & Risk Management holds every requirement, its controls and its audit trail.

3 of 5 requirement areas draw on more than one application

  • Art. 20GovernanceGRC
  • Art. 21(1)Appropriate and proportionate measuresGRC
  • Art. 21(2)The ten risk-management measuresGRCTPRMUEM
  • Art. 21(3)–(5)Supply-chain assessments, corrective measures and technical requirementsGRCTPRMUEM
  • Art. 23Incident reportingGRCUEM

Indicative mapping from the requirement areas above; your scoping call confirms it for your organisation.

What you work in every day

Sample screens from the workspace, with sample data.

Compliance & Risk Management
Third-Party Risk Management

From scoping to a programme you can defend

  1. Confirm scope and status

    Check your sector against Annexes I and II and your size against the medium-sized enterprise threshold, then establish under national law whether you are an essential or an important entity. In Italy the reference is Legislative Decree 138/2024, and ACN notifies entities of their inclusion in the national NIS list.

  2. Put the management body in charge

    Have the management body approve the risk-management measures, set how often it reviews them and plan its own training. Article 20 makes approval, oversight and training its responsibility, not the IT department’s.

  3. Assess the ten measures

    Run the risk analysis, then assess each Article 21(2) measure for applicability, implementation status and existing evidence. Record why each measure is proportionate to your exposure, your size and the impact an incident would have. The gaps become your plan.

  4. Close the gaps and prepare to report

    Assign owners and deadlines to corrective actions, assess your direct suppliers, and write the incident procedure around the Article 23 clock: who decides that an incident is significant, who sends the early warning within 24 hours, the notification within 72 hours and the final report within one month. Then rehearse it.

  5. Test, review and keep evidence current

    The Directive creates no NIS2 certificate: authorities supervise essential entities proactively and important entities when there are signs of non-compliance. Test the effectiveness of your measures, report the results to the management body and renew evidence before it expires.

Article 21 tells entities to take relevant European and international standards into account, so work done on them counts towards NIS2. In ResilientX Security GRC, NIS2, ISO 27001, DORA and GDPR ship as cross-mapped libraries, so a control assessed once carries its status everywhere it applies.

NIS2 questions, answered

Who has to comply with NIS2?

Public and private entities of a type listed in Annex I (sectors of high criticality) or Annex II (other critical sectors) that are medium-sized or larger and provide services or carry out activities in the EU. Some are in scope whatever their size, including providers of public electronic communications networks or services, trust service providers, TLD name registries and DNS service providers. Your national transposition law decides whether you are in scope; in case of doubt, ask your legal counsel.

What is the difference between essential and important entities?

Both must apply the same risk-management measures and report significant incidents. Essential entities are, broadly, large organisations in the Annex I sectors plus certain entities the Directive names whatever their size; the other entities in scope are important. The difference lies in supervision and fines. Essential entities are supervised proactively as well as after the fact and face maximum fines of at least €10 million or 2% of worldwide annual turnover, whichever is higher. Important entities are supervised when there is evidence of non-compliance and face maximum fines of at least €7 million or 1.4%.

When do significant incidents have to be reported?

In stages, to your CSIRT or competent authority: an early warning without undue delay and within 24 hours of becoming aware of the incident, an incident notification within 72 hours, an intermediate report if requested, and a final report no later than one month after the notification. An incident is significant if it has caused or can cause severe operational disruption of your services or financial loss, or considerable damage to other people or organisations.

Is the management body personally involved?

Yes. Under Article 20 the management body approves the cybersecurity risk-management measures, oversees their implementation and can be held liable for infringements, and its members must follow cybersecurity training. National law sets how that liability works in practice, so it is a point to review with your counsel.

How does NIS2 apply in Italy?

Through Legislative Decree 138/2024, with the National Cybersecurity Agency (ACN) as the competent authority. ACN’s basic security measures (Resolution 379907/2025) are built on the 2025 edition of the national framework, the FNCDP: 37 measures for important entities and 43 for essential entities. ACN allowed 18 months from the notice of inclusion in the national NIS list to adopt them, which for the entities on the first list meant October 2026.

Is there a NIS2 certification, and is ISO 27001 enough?

The Directive creates no NIS2 certificate: national authorities supervise compliance. ISO 27001 certification helps, because an ISMS covers much of Article 21, but on its own it does not satisfy management-body accountability under Article 20, the Article 23 reporting deadlines or national requirements. ResilientX Security is not a certification body and does not give legal advice; in ResilientX Security GRC the two libraries are cross-mapped, so shared controls are assessed once.

See your NIS2 programme running in 30 minutes

  • How the 20 controls of Articles 20, 21 and 23 are assessed, owned and linked to policies and evidence
  • How direct suppliers are assessed and monitored for Article 21(2)(d), from questionnaire to continuous rating
  • Where the ISO 27001, DORA or GDPR controls you already have cover NIS2 requirements
Prefer email? Write to info@resilientx.com

Pick a time that works for you

30 minutesVideo callNo commitment