ResilientX

Meet CMMC 2.0 Level 2 and stay eligible for US defence work

110 controls pre-loaded in ResilientX Security GRC

Cybersecurity Maturity Model Certification (CMMC) 2.0, Level 2

Issuer
US Department of Defense (Department of War)
Level 2 baseline
110 requirements of NIST SP 800-171 Rev. 2
In force
32 CFR Part 170 since 16 Dec 2024; contract clauses since 10 Nov 2025
Assessment
Self-assessment or C3PAO, every three years, plus an annual affirmation

At a glance · Cybersecurity Maturity Model Certification (CMMC) 2.0, Level 2

What is CMMC 2.0 Level 2?

The Cybersecurity Maturity Model Certification (CMMC) is how the US Department of Defense verifies that its contractors protect Federal Contract Information (FCI) and Controlled Unclassified Information (CUI). Level 2 applies where CUI is processed, stored or transmitted on contractor systems. It requires all 110 security requirements of NIST SP 800-171 Rev. 2, confirmed by a self-assessment or by a certification assessment from an authorised C3PAO, renewed every three years and affirmed every year in the DoD’s SPRS system.

The requirements apply to international and domestic companies alike and flow down to subcontractors at every tier that handle CUI; the rule allows no partial exemption for foreign contractors. For a European aerospace or defence supplier that receives CUI from a US prime, a CMMC status can become a condition of award.

Phase 1 started on 10 November 2025 with self-assessments. Phase 2, which would have made C3PAO assessments the norm for Level 2 from 10 November 2026, was suspended by the Department on 13 July 2026 pending a programme review. Phase 1 self-assessment requirements stay in force, and the NIST SP 800-171 obligations in existing defence contracts are unchanged.

Who it applies to

  • DoD prime contractors and subcontractors at any tier that process, store or transmit CUI on their own systems
  • European and other non-US suppliers whose DoD subcontract flows down a Level 2 requirement
  • Cloud and managed-service providers used for CUI, which the contractor must document and bring into its assessment scope
  • Suppliers that handle only FCI, not CUI, need Level 1 (Self) rather than Level 2

Key dates

  1. 2024

    In force

    32 CFR Part 170 since 16 Dec 2024

  2. 2025

    In force

    Contract clauses since 10 Nov 2025

What CMMC Level 2 requires

Level 2 groups the 110 requirements of NIST SP 800-171 Rev. 2 into 14 domains, and the 17 Level 1 practices that protect FCI are part of the same set. The 12 domains below hold 102 of the requirements; the other two, Maintenance (6) and Personnel Security (2), are just as mandatory and sit in the same pre-loaded library.

Where the requirements sit

  1. AC22 controls

    Access Control

    Limit system and CUI access to authorised users, processes and devices, with least privilege, separation of duties, session controls and secure remote, wireless and mobile access.

    22% of the controls

  2. AT3 controls

    Awareness and Training

    Make managers, administrators and users aware of security risks, train them for their roles and teach them to spot and report insider-threat indicators.

    3% of the controls

  3. AU9 controls

    Audit and Accountability

    Create, protect and review audit logs so that unauthorised activity can be traced to an individual user and investigated.

    9% of the controls

  4. CM9 controls

    Configuration Management

    Baseline configurations and inventories, controlled changes with security impact analysis, least functionality and authorised software only.

    9% of the controls

  5. IA11 controls

    Identification and Authentication

    Unique identification, multifactor authentication for privileged and network access, replay-resistant authentication and password rules.

    11% of the controls

  6. IR3 controls

    Incident Response

    An operational, tested incident-handling capability that tracks, documents and reports incidents.

    3% of the controls

  7. MP9 controls

    Media Protection

    Protect, mark, control, sanitise and encrypt paper and digital media holding CUI, including removable media and backups.

    9% of the controls

  8. PE6 controls

    Physical Protection

    Limit and log physical access, escort visitors, manage access devices and protect CUI at alternate work sites.

    6% of the controls

  9. RA3 controls

    Risk Assessment

    Assess risk periodically, scan for vulnerabilities and remediate them according to risk.

    3% of the controls

  10. CA4 controls

    Security Assessment

    Assess controls periodically, run plans of action for deficiencies, monitor continuously and keep the system security plan current.

    4% of the controls

  11. SC16 controls

    System and Communications Protection

    Boundary protection, network segmentation, FIPS-validated encryption of CUI in transit and at rest, and control of collaborative devices, mobile code and VoIP.

    16% of the controls

  12. SI7 controls

    System and Information Integrity

    Fix flaws promptly, protect against and scan for malicious code, act on security alerts and monitor systems for attacks.

    7% of the controls

Ready-made control library

110 controls pre-loaded in ResilientX Security GRC

Book a demo

How the ResilientX Security platform covers CMMC 2.0 Level 2

ResilientX Security is not a C3PAO and does not assess or certify anyone. We give your team the workspace, the supplier oversight and the security testing to reach the assessment prepared, with evidence you can show.

Compliance

Compliance & Risk Management

  • All 110 requirements, ready on day one

    The CMMC 2.0 Level 2 library comes pre-loaded in ResilientX Security GRC, with guidance for every requirement in English and Italian. Mark applicability and implementation status and follow progress domain by domain.

  • Evidence, policies and POA&M items with owners

    Link versioned policies and evidence with expiry dates to each requirement, and turn every NOT MET result into a remediation task with an owner and a deadline, so open items stay inside the 180-day POA&M window.

  • Scope and cross-map once

    Keep the assets, systems and processes in your CUI scope in the Inventory module, and link equivalent controls across frameworks so evidence collected for ISO 27001 is reused instead of gathered twice.

Learn more — Compliance & Risk Management

Third-Party Risk Management

  • Flow-down to your own suppliers

    If you pass CUI to sub-tier suppliers, the requirement goes with it. Send them security questionnaires built on your own template, collect their evidence and certifications, and monitor their external cyber posture continuously.

Learn more — Third-Party Risk Management

CMMC 2.0 Level 2 on one platform

  • Controls
  • Evidence
  • Risks
  • Suppliers
  • Findings

Resilience

Unified Exposure Management

  • External exposure and vulnerability scanning

    Continuously discover internet-facing assets, exposed services, vulnerabilities, cloud misconfigurations and leaked credentials, supporting the scanning and monitoring practices in the RA and SI domains.

Learn more — Unified Exposure Management

Service · Advanced Penetration Testing

Penetration tests on your boundary

Expert-led tests of internal and external networks, segmentation, web applications, APIs and OT/ICS environments give independent evidence that boundary protection and segmentation work as documented.

See the service

Requirement by requirement

Where each application feeds a requirement area with evidence or day-to-day operations. Compliance & Risk Management holds every requirement, its controls and its audit trail.

8 of 12 requirement areas draw on more than one application

  • ACAccess ControlGRCCTI
  • ATAwareness and TrainingGRC
  • AUAudit and AccountabilityGRC
  • CMConfiguration ManagementGRCUEM
  • IAIdentification and AuthenticationGRCCTI
  • IRIncident ResponseGRCUEM
  • MPMedia ProtectionGRC
  • PEPhysical ProtectionGRC
  • RARisk AssessmentGRCUEM
  • CASecurity AssessmentGRCUEM
  • SCSystem and Communications ProtectionGRCUEM
  • SISystem and Information IntegrityGRCUEM

Indicative mapping from the requirement areas above; your scoping call confirms it for your organisation.

What you work in every day

Sample screens from the workspace, with sample data.

Compliance & Risk Management
Third-Party Risk Management

Your path to CMMC Level 2

  1. Confirm the level and scope your CUI

    Check the solicitation or subcontract for the CMMC level and assessment type, then map where CUI is processed, stored and transmitted: people, systems, sites and service providers. A tight enclave keeps the scope manageable.

  2. Run a gap assessment against all 110

    Score each requirement against its NIST SP 800-171A assessment objectives and record what is MET and NOT MET, with the evidence behind each answer.

  3. Close the gaps and write the SSP

    Implement the missing practices, write the System Security Plan that describes your environment, and plan any remaining gaps with owners and dates.

  4. Self-assess or book a C3PAO

    For Level 2 (Self), post your score in SPRS and have a senior official affirm it. For Level 2 (C3PAO), choose an authorised assessor from the CMMC Accreditation Body’s public list. A score of at least 88 can give conditional status while eligible open items are closed within 180 days.

  5. Keep it current

    Affirm continuing compliance every year, keep evidence and the SSP up to date, and reassess every three years.

A certificate under another standard does not replace a CMMC assessment, because each of the 110 requirements is scored on its own. What carries over is the work: the controls and evidence you already maintain.

CMMC Level 2: frequently asked questions

Does CMMC apply to a European company?

Yes, when a DoD contract or subcontract requires you to process, store or transmit FCI or CUI on your own systems. The rule applies to international and domestic companies alike, flows down through every subcontract tier and does not allow partial exemptions for foreign contractors. Any arrangement for foreign businesses has to come from government-to-government agreements.

Do we need a self-assessment or a C3PAO assessment?

The solicitation or subcontract states it. In Phase 1, which began on 10 November 2025, the DoD intends to require Level 1 or Level 2 self-assessments, but it can ask for Level 2 (C3PAO) at its discretion. Phase 2 was meant to make C3PAO assessments the norm from 10 November 2026, but the Department suspended it on 13 July 2026 pending a review.

What did the July 2026 suspension change?

It paused the Phase 2 rollout of mandatory C3PAO assessments pending a review of the programme by a CMMC Reform Task Force. Phase 1 self-assessment requirements stay in force, SPRS scores and annual affirmations are still due where contracts require them, and DFARS 252.204-7012 still requires NIST SP 800-171 for covered defense information. Check each solicitation for the current requirement.

Can we bid with open gaps?

Only within limits. A Level 2 score of at least 88 out of 110 can give a conditional status with a plan of action and milestones (POA&M), but only for requirements worth one point, with a narrow exception for encryption that is not FIPS-validated. A few requirements, such as the System Security Plan, can never be deferred, and every item must be closed within 180 days or the conditional status expires.

How long does a Level 2 status last?

Three years, for both self-assessments and C3PAO certification assessments. In between, a senior affirming official must confirm continuing compliance in SPRS every year and after each assessment.

Does ResilientX Security certify CMMC?

No. ResilientX Security is not a C3PAO and does not perform CMMC assessments or issue certifications. Level 2 certification assessments are carried out by C3PAOs authorised through the CMMC Accreditation Body. We help you prepare: the requirement library, evidence and remediation tracking, supplier assessments and security testing.

See your CMMC Level 2 programme in a live workspace

  • The 110 requirements across 14 domains, with guidance in English and Italian
  • How to track gaps, evidence and POA&M items with owners and deadlines
  • How to assess the sub-tier suppliers you flow CUI requirements down to
Prefer email? Write to info@resilientx.com

Pick a time that works for you

30 minutesVideo callNo commitment